The Tireless 12V 14Ah Rechargeable Sealed Lead-Acid (SLA) / AGM Battery is a heavy-duty, high-capacity valve-regulated deep-cycle power storage solution engineered by Tireless for uninterruptible power supply (UPS) systems, power inverters, rechargeable standing/desk fans, solar power installations, public address (PA) systems, and emergency lighting setups.

Highlights

  • Absorbed Glass Mat (AGM) VRLA Construction
  • High 14Ah Deep-Cycle Capacity
  • Solid Copper Alloy Terminals
  • Low Self-Discharge & Extended Shelf Life

Key specs

Capacity
14
Voltage
12
01

Overview

The Tireless 12V 14Ah Rechargeable Sealed Lead-Acid (SLA) / AGM Battery is a heavy-duty, high-capacity valve-regulated deep-cycle power storage solution engineered by Tireless for uninterruptible power supply (UPS) systems, power inverters, rechargeable standing/desk fans, solar power installations, public address (PA) systems, and emergency lighting setups.

Utilizing advanced Absorbed Glass Mat (AGM) VRLA dry-cell technology, this maintenance-free battery permanently suspends liquid electrolyte within fine glass fiber separators. This design ensures a 100% leak-proof, spill-proof construction that operates safely in any orientation. Delivering a nominal 12 Volts DC output with an expanded 14 Ampere-Hour (14Ah / 14,000 mAh) storage capacity (168 Watt-hours nominal energy), the Tireless 12V 14Ah battery delivers reliable backup runtime, low internal resistance, and efficient high-current discharge during unexpected electrical grid outages.

02

Key Features & Highlights

Absorbed Glass Mat (AGM) VRLA Construction

Valve-regulated sealed lead-acid architecture eliminates free liquid acid, making the battery completely leak-proof, spill-proof, and maintenance-free with zero water replenishment required.

High 14Ah Deep-Cycle Capacity

Delivers 14 Ampere-Hours of energy storage (~168 Wh), providing almost double the backup runtime of standard 7Ah or 9Ah UPS batteries for desktop PCs, workstations, and network routers.

Solid Copper Alloy Terminals

Fitted with heavy-duty solid copper blade terminals (F2 / T2 style) that minimize contact resistance, prevent terminal corrosion, and reduce heat buildup under high current draws.

Low Self-Discharge & Extended Shelf Life

Constructed with high-purity lead-calcium grid alloy plates that maintain low self-discharge rates (<3% capacity loss per month at 25°C), allowing long-term storage without rapid degradation.

Impact-Resistant ABS Flame-Retardant Casing

Enclosed in a rugged, shock-absorbing ABS synthetic housing engineered to withstand physical impacts, vibration, and elevated environmental operating temperatures.

Universal Equipment Compatibility

Standardized form factor and terminal configuration ensure drop-in replacement compatibility across a broad array of UPS brands, rechargeable fans, solar charge controllers, and security systems.

03

Key specs

Capacity
14
Voltage
12
04

Technical Specifications

Product Name
Tireless Rechargeable UPS Battery 12V 14Ah
Brand / Manufacturer
Tireless
Battery Chemistry
Valve-Regulated Sealed Lead-Acid (VRLA) / AGM Dry Cell
Nominal Voltage
12.0 Volts DC
Rated Storage Capacity
14.0 Ah (14,000 mAh @ 20-Hour Rate)
Nominal Energy Rating
~168 Watt-Hours (Wh)
Terminal Type
Heavy-Duty Solid Copper Faston Blade Terminals (F2 / T2)
Standby Charge Voltage
13.5V to 13.8V DC at 25°C (77°F)
Cycle Use Charge Voltage
14.4V to 15.0V DC at 25°C (77°F)
Maximum Initial Charging Current
4.2 Amps (Max)
Self-Discharge Rate
<3% per month at 25°C
Container Material
High-Impact Flame-Retardant ABS Resin
Operating Temperature Range
Discharge: -15°C to 50°C; Charge: 0°C to 40°C
Approximate Dimensions (L × W × H)
151 mm × 98 mm × 95 mm (Total Height with Terminals: ~98 mm)
Approximate Weight
~3.4 kg (7.5 lbs)
05

Primary Applications & Use Cases

  1. Uninterruptible Power Supply (UPS) Systems: Serves as a high-capacity replacement battery for home and office desktop UPS backup units (APC, Mercury, Blue Gate, Sukam, Luminous), extending hold-up runtime for PCs, monitors, and networking gear.
  2. Rechargeable Standing & Desk Fans: Powers high-draw 12V rechargeable standing fans and solar desk fans during prolonged power outages.
  3. Power Inverters & Renewable Solar Storage: Connects to small-scale 12V solar charge controllers and power inverters to store solar energy for nighttime lighting and small appliances.
  4. Security, CCTV & Fire Safety Systems: Delivers continuous 24/7 backup power for CCTV camera DVR/NVR recorders, electronic door access control locks, and automated gate openers.
  5. Public Address (PA) Systems & Portable Audio: Drives portable PA speakers, megaphones, wireless microphone receiver bases, and emergency lighting units.
06

Maintenance & Operating Best Practices

Initial Charging

Charge the battery fully for 8–10 hours prior to first deployment to ensure maximum initial discharge capacity.

Avoid Deep Discharges

Recharges should be initiated promptly after use; leaving the battery in a fully discharged state leads to irreversible plate sulfation and capacity loss.

Storage Conditions

Store in a cool, dry place (20°C–25°C recommended). Refresh charge every 6 months if stored unused for long periods.

Proper Terminal Connection

Ensure copper terminal connectors are tightly fitted to prevent sparking, arcing, or excessive heat buildup during high-amp startup loads.