The Tireless 12V 14Ah Rechargeable Sealed Lead-Acid (SLA) / AGM Battery is a heavy-duty, high-capacity valve-regulated deep-cycle power storage solution engineered by Tireless for uninterruptible power supply (UPS) systems, power inverters, rechargeable standing/desk fans, solar power installations, public address (PA) systems, and emergency lighting setups.
Highlights
- Absorbed Glass Mat (AGM) VRLA Construction
- High 14Ah Deep-Cycle Capacity
- Solid Copper Alloy Terminals
- Low Self-Discharge & Extended Shelf Life
Key specs
- Capacity
- 14
- Voltage
- 12
Overview
The Tireless 12V 14Ah Rechargeable Sealed Lead-Acid (SLA) / AGM Battery is a heavy-duty, high-capacity valve-regulated deep-cycle power storage solution engineered by Tireless for uninterruptible power supply (UPS) systems, power inverters, rechargeable standing/desk fans, solar power installations, public address (PA) systems, and emergency lighting setups.
Utilizing advanced Absorbed Glass Mat (AGM) VRLA dry-cell technology, this maintenance-free battery permanently suspends liquid electrolyte within fine glass fiber separators. This design ensures a 100% leak-proof, spill-proof construction that operates safely in any orientation. Delivering a nominal 12 Volts DC output with an expanded 14 Ampere-Hour (14Ah / 14,000 mAh) storage capacity (168 Watt-hours nominal energy), the Tireless 12V 14Ah battery delivers reliable backup runtime, low internal resistance, and efficient high-current discharge during unexpected electrical grid outages.
Key Features & Highlights
Absorbed Glass Mat (AGM) VRLA Construction
Valve-regulated sealed lead-acid architecture eliminates free liquid acid, making the battery completely leak-proof, spill-proof, and maintenance-free with zero water replenishment required.
High 14Ah Deep-Cycle Capacity
Delivers 14 Ampere-Hours of energy storage (~168 Wh), providing almost double the backup runtime of standard 7Ah or 9Ah UPS batteries for desktop PCs, workstations, and network routers.
Solid Copper Alloy Terminals
Fitted with heavy-duty solid copper blade terminals (F2 / T2 style) that minimize contact resistance, prevent terminal corrosion, and reduce heat buildup under high current draws.
Low Self-Discharge & Extended Shelf Life
Constructed with high-purity lead-calcium grid alloy plates that maintain low self-discharge rates (<3% capacity loss per month at 25°C), allowing long-term storage without rapid degradation.
Impact-Resistant ABS Flame-Retardant Casing
Enclosed in a rugged, shock-absorbing ABS synthetic housing engineered to withstand physical impacts, vibration, and elevated environmental operating temperatures.
Universal Equipment Compatibility
Standardized form factor and terminal configuration ensure drop-in replacement compatibility across a broad array of UPS brands, rechargeable fans, solar charge controllers, and security systems.
Key specs
- Capacity
- 14
- Voltage
- 12
Technical Specifications
- Product Name
- Tireless Rechargeable UPS Battery 12V 14Ah
- Brand / Manufacturer
- Tireless
- Battery Chemistry
- Valve-Regulated Sealed Lead-Acid (VRLA) / AGM Dry Cell
- Nominal Voltage
- 12.0 Volts DC
- Rated Storage Capacity
- 14.0 Ah (14,000 mAh @ 20-Hour Rate)
- Nominal Energy Rating
- ~168 Watt-Hours (Wh)
- Terminal Type
- Heavy-Duty Solid Copper Faston Blade Terminals (F2 / T2)
- Standby Charge Voltage
- 13.5V to 13.8V DC at 25°C (77°F)
- Cycle Use Charge Voltage
- 14.4V to 15.0V DC at 25°C (77°F)
- Maximum Initial Charging Current
- 4.2 Amps (Max)
- Self-Discharge Rate
- <3% per month at 25°C
- Container Material
- High-Impact Flame-Retardant ABS Resin
- Operating Temperature Range
- Discharge: -15°C to 50°C; Charge: 0°C to 40°C
- Approximate Dimensions (L × W × H)
- 151 mm × 98 mm × 95 mm (Total Height with Terminals: ~98 mm)
- Approximate Weight
- ~3.4 kg (7.5 lbs)
Primary Applications & Use Cases
- Uninterruptible Power Supply (UPS) Systems: Serves as a high-capacity replacement battery for home and office desktop UPS backup units (APC, Mercury, Blue Gate, Sukam, Luminous), extending hold-up runtime for PCs, monitors, and networking gear.
- Rechargeable Standing & Desk Fans: Powers high-draw 12V rechargeable standing fans and solar desk fans during prolonged power outages.
- Power Inverters & Renewable Solar Storage: Connects to small-scale 12V solar charge controllers and power inverters to store solar energy for nighttime lighting and small appliances.
- Security, CCTV & Fire Safety Systems: Delivers continuous 24/7 backup power for CCTV camera DVR/NVR recorders, electronic door access control locks, and automated gate openers.
- Public Address (PA) Systems & Portable Audio: Drives portable PA speakers, megaphones, wireless microphone receiver bases, and emergency lighting units.
Maintenance & Operating Best Practices
Initial Charging
Charge the battery fully for 8–10 hours prior to first deployment to ensure maximum initial discharge capacity.
Avoid Deep Discharges
Recharges should be initiated promptly after use; leaving the battery in a fully discharged state leads to irreversible plate sulfation and capacity loss.
Storage Conditions
Store in a cool, dry place (20°C–25°C recommended). Refresh charge every 6 months if stored unused for long periods.
Proper Terminal Connection
Ensure copper terminal connectors are tightly fitted to prevent sparking, arcing, or excessive heat buildup during high-amp startup loads.
Customer reviews